                                                                                        Mounting / Adjusting Cartridges

                            5      3  B Mounting of Cartridges with Adjustment                                                 Cartridge Face Mills

                         1               1. Lubricate the screws under the head and on the thread (preferably
4                                            with copper paste).

                        2                2. Clean the cartridges and their pockets located in the milling cutter.
                                         3. Introduce the first cartridge into its pocket and check it moves freely.
44                                       4. Introduce screws No. 1 and No. 2 while pushing the cartridge against its

6                                            axial setting track, tighten screw No. 1.
                                         5. Mount an insert with ground periphery which will serve as a gauge.
 7                                       6. Gauge the height of the first mounted cartridge, then set the pre-setter
 7A
  7                                          to zero. Set the pre-setter so that the measuring system indicates
                                             +0,02 mm.
    7A                                   7. Slightly loosen both screws; reverse the cartridge to just below zero in
                                             relation to pre-set +0,02mm and again moderately tighten screw No. 1.
               7                             Using screw No. 2 advance the cartridge to zero. Then loosen screw No. 2.

8C                                    Instructions for Tightening
8B                                    After height zero has been reached:

8D                             8A                A	 Lock screw No. 1 securely with the extended allen key (tightening
8E                                                  torque14 Nm). When doing this it is possible that the cartridge may
                                                    reverse a little.
 8D
   8E                                            B	 Re-tighten screw No. 2 to jack cartridge back to zero position.

                                         8. To adjust the other cartridges, proceed as follows:
                                                 A	 Mount the cartridge using screw No. 1 which must be moderately
                                                 				tightened.

                                                 B	 Mark, as a reference face with a red felt-tipped pen, the insert from the
                                                 		 preceding cartridge and introduce it so as to use the same wiper edge.	
                                                 C	 Rotate the cutter (8A) with the mounted insert (8B) in the position of

                                                    the lens (8C) on the pre-setter to measure the height.

                                                 D	 Introduce screw No. 2 which will help push the cartridge up to position
                                                    zero on the dial. Loosen the screw.

                                                 E	 From this point onwards, follow the tightening instructions
                                                    described above

                                                 F 	Then tighten all screws Nr.2 moderately.

                                         9. Once the mounting of the cartridges is complete, mount the indexable
                                             inserts.

                                      NOTE: By proceeding in this way with the mounting of cartridges, the insert seats
                                      should all be at a precise height (± 0,002); only variations in the insert
                                      dimensions will then influence the axial runout of the milling cutter.